| SPECIFICATION | UNITS / FEATURES | 
| MODELS 
 | The SAL Saline Chlorinators and Chlorination Systems consists of various modular units with variable chlorine production capacities. | 
| TYPE | In-line - Commercial Hypochlorite Plant | 
| NO. UNITS | Plant can be designed to comfortably meet chlorine production requirements with single rectifier/cell modular units. If system back up is required or desirable, systems can be designed to tolerate multiple cell shut-down without affecting the rest of the system. | 
| CHLORINE PRODUCTION | From 50 grams per hour to 50 kilograms per hour or greater. | 
| SALT CONCENTRATION | The system relies on the presence of salt in the water, ranging from seawater concentrations (3.5%) to as little as 5,500 ppm salt concentrations. | 
| WATER TREATMENT VOLUME
 | The pre-engineered range is designed to meet the chlorine requirements of any water volume or water flow rate. Where pre-engineered models are not suited to a particular application, units are tailor designed. | 
| RECTIFIER | Designed to Australian Standards AS3108 & AS2374. | 
| Cabinet | Thickness - 1.6mm | 
|  | Finish - Powder coated zinc anneal steel to 85 microns. | 
| Power Supply | Up to and including 330 grams/hr - Single phase power supply. | 
| > 330 rams/hour - 3 Phase power is required. | 
| Single Phase | 3 Phase Rectification | 
| Primary Input Voltage | 110-240V | 415V | 
| RECTIFIER CONTROL | - Transformers are tapped for world power variation. | 
| Equipment | - Variable Chlorine Control | 
|  | - Ammeter (conventional) | 
| - Main Power On Switch | 
| - Rectifier Power On Switch | 
| - Primary & Secondary alarm | 
| - Lamps displaying: Power On, Rectifier On, Water Flow Fault, Temperature Alarm | 
| Soft Start Up | For maximum cell protection the unit is fitted with thyristor controls, soft start auto voltage and amperage romping. | 
| Cooling System | Air or Fan cooled (on larger units). | 
| ELECTRODE CELL(S) | Type - Monopolar, solid 1.6mm solid plate electrodes. | 
| Material | Cathode - Solid Titanium plate. | 
| Anode - Solid Titanium plate, coated with SC6 industrial quality coatings. | 
| Cell Cleaning | Up to 330g/h Cl - Removal of cell and manual acid cleaning with mild acid solution, facilitated by acid cleaning chamber. | 
| Above 330g/h Cl - Provide a semi-automatic, manual valve operated acid wash system, incorporating pump, check valves and acid tank. | 
| Plumbing | Pipes, fittings and valves - Industrial grade heavy walled PVC or CPVC. Factory tested to 400 kPa. Electrode Inspection facilitated by clear PVC inspection portal in cell chamber. | 
| Minimum Water Flow                           | The electrode cells require minimum water flow rates to ensure efficient heat transfer and maximum efficiency. Refer to Commercial Plant Specifications. |